Switch monitoring configuration
Benefits:By effectively monitoring the position of the diaphragm, feeding back the collected information of switching state to the control room in real time, the valve switching state is accurately judged, which solves the problem that the valve switching state cannot be mastered effectively in practical engineering, and greatly improves the safety and stability of irrigation engineering.
Working principle:monitoring the position of diaphragm to determine the opening and closing state of valve.
Scope of application:DN40 DN50 DN80 DN100
| Technical parameters : |
Controller needs to support the switch to collect data |
| Maximum current |
0.5A |
| Maximum voltage |
100VDC |
Technical Specification
| Sizes |
DN50 . DN80 DN100 |
| Material |
Glass-fiber Reinforced PA66 |
| Configurations |
Manually Controlled Valve |
| Electric Valve |
| Pressure Reducing Valve |
| Max.Pressure Rating |
bar |
10 |
| psi |
145 |
| Max. Temperature |
℃ |
50 |
| ℉ |
122 |
Advantage
omparing to the seperate water meter + valve installation way, our water meter valve kit can save the installation space and cost, reducing the cost of irrigation system.

| DN (mm) |
Length L (mm) |
Height H (mm) |
Flange Connection |
| Flange Outer Diameter D |
Center Diameter of Bolt Hole D1 |
Outlet Connect D2 |
| 50 |
430 |
257 |
200 |
125 |
Thread BSPT/NPT |
| 80 |
500 |
277 |
200 |
160 |
M16×Thread BSPT/NPT16 |
| 80 |
500 |
277 |
200 |
160 |
Solvent Welding 88.9/90.3 |
| 100 |
520 |
287 |
220 |
180 |
Solvent Welding 110/114.3 |
Performance Data
|
|
Accuracy |
DN50 |
DN80 |
DN100 |
| 2” |
3” |
4” |
| Q1 (Minimun flow) |
m³/h |
±5% |
2.5 |
3.94 |
6.25 |
| Q2 (Transitional flow) |
±2% |
4 |
6.3 |
10 |
| Q3 (Normal flow) |
±2% |
40 |
63 |
100 |
| Q4 (Peak flow,short tim) |
±2% |
50 |
78.75 |
125 |
| Min Reading |
m³ |
|
0.001 |
0.001 |
0.001 |
| Min Reading |
|
9999999 |
9999999 |
9999999 |
Valve Controller (Options)
Parameter:
| Battery |
18650 lithium battery 3.6v 2150mAh |
| IP Grad |
IP68 |
| Working Tempertur |
-40℃~ +85 |
| Using a common interface protocol, Customized access to multiple cloud control system is availably |
Main Functions:
1.Bluetooth Control:
- Digital Channel:2.4GHz
- Transmission Baut Rate:Max 1Mbps
- Distance:Max 100m
2 ,Wireless Communication Modes:
2.1) GPRS:
- Digital Channel:850/900/1800/1900MHz
- Transmission Baut Rate:最大 85.6kbps
- Protocol:TCP/HTT
2.2)LoRa:
- Digital Channel:433 MHz
- Transmission Baut Rate:2400/9600bps
- Protocol:LoRaWA
3,Solenoid Valve Control:
- Solenoid Valves:2 channels,(6-12V pulse)
- Pulse Time:100ms
4,Signal Collection:
- Digital Singal Collection:RS485 2 channels,
- Analog Digital Collection:Current(4-20mA)and Voltage(0-5V)2 channels
- Switch Input Collection:1 channel
Other Funtions:
- Remote control of valve
- Real-time two-way reading function
- Data recording function
- Leak data management function
- Reflux data management function
- Working life warning function
- Prevention and early warning function
- Automatic alarm function
Installation
1. Determine the port size of water meter valve, should get idea of the dimension of the pipe firstly , and the flow rate of the pipe have to appropriate to the one of water meter.
2. The water meter is connected to the valve inlet, part, make sure that the arrow on the valve body shows the same direction as the direction of the flow .
3. The flange must be connected to the pipe before install the water meter, then fix the water meter valve to the pipe line.
4. Water meter valve outlet connection is female threaded connection: BSPT or NPT
5. In order to avoid the turbulent flow affect metering accuracy, it is recommended to install a straight pipe that 10 times longer than the pipe in front of the water meter valve and a straight pipe with 5 times longer behind it.
6. Flush the pipe to remove solid impurities before installation.
7. The water meter valve must be keep working accurately and reliably under conditions of flushing